Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorYes
Integrated earth fault protectionNo
Overload release current setting500 - 1250A
Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release2500 - 18750A
Adjustment range short-term delayed short-circuit release750 - 12500A
With integrated under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu1250A
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Number of poles3
Complete device with protection unitYes
Motor drive optionalYes
Motor drive integratedNo
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Degree of protection (IP)IP40
Rated voltage690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33565

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Integrated earth fault protection

Overload release current setting

500 .. 1250A

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

2500 .. 18750A

Adjustment range short-term delayed short-circuit release

750 .. 12500A

With integrated under voltage release

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

1250A

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Number of poles

3

Complete device with protection unit

Motor drive optional

Motor drive integrated

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Degree of protection (IP)

IP40

Rated voltage

690 .. 690V

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.