  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Rated permanent current Iu2000A
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalNo
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Number of poles3
Complete device with protection unitNo
Motor drive integratedNo
With integrated under voltage releaseNo
Degree of protection (IP)IP30
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

34007

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Rated permanent current Iu

2000A

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Motor drive optional

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Number of poles

3

Complete device with protection unit

Motor drive integrated

With integrated under voltage release

Degree of protection (IP)

IP30