  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu2000A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Complete device with protection unitNo
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Motor drive optionalNo
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Number of poles4
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Motor drive integratedNo
Degree of protection (IP)IP30
Type of control elementRocker lever
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

34009

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

2000A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Integrated earth fault protection

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Motor drive integrated

Degree of protection (IP)

IP30

Type of control element