Degree of protection (IP)IP30
Number of poles4
Type of control elementPush button
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu630A
Overload release current setting0 - 0A
Motor drive integratedNo
Rated voltage690 - 690V
Type of electrical connection of main circuitRail connection
Motor drive optionalYes
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact5
Adjustment range undelayed short-circuit release0 - 0A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitBack connection
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

47209

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP30

Number of poles

4

Type of control element

Push button

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

630A

Overload release current setting

0 .. 0A

Motor drive integrated

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Rail connection

Motor drive optional

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as change-over contact

5

Adjustment range undelayed short-circuit release

0 .. 0A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Back connection

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit