Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP30
Type of control elementPush button
Number of poles3
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu2500A
Motor drive integratedNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Overload release current setting- - -A
Rated voltage690 - 690V
Motor drive optionalYes
Type of electrical connection of main circuitRail connection
Number of auxiliary contacts as change-over contact5
Adjustment range undelayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Integrated earth fault protectionNo
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitBack side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

48300

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP30

Type of control element

Push button

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

2500A

Motor drive integrated

Device construction

Built-in device slide-in technique (withdrawable)

Overload release current setting

- .. -A

Rated voltage

690 .. 690V

Motor drive optional

Type of electrical connection of main circuit

Rail connection

Number of auxiliary contacts as change-over contact

5

Adjustment range undelayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Integrated earth fault protection

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Back side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.