Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
System configuration IT
Yes
System configuration DC
No
System configuration TN-C-S
No
System configuration TN
No
System configuration TN-S
No
System configuration TT
No
Number of conductors (without earthing)
1
System configuration TN-C
No
System configuration other
No
Nominal voltage AC
660V
Nominal voltage DC
0V
Max. discharge surge current (8/20)
40kA
Nominal discharge surge current (8/20)
40kA
Max. PV-voltage
0V
Max. continuous voltage DC
0V
Max. continuous voltage AC
1000V
Voltage protection level L-N
1kV
Integrated backup fuse
No
Max. overcurrent protection device, parallel connection (fuse)
0A
Mounting method
On basic element
Integrated short-circuit protection selective to fuse gG
0A
Max. conductor cross section flexible (fine-strand)
150mm²
With remote signalling contact
No
Voltage protection level N-PE
0.66kV
Max. conductor cross section solid (solid, stranded)
150mm²
Construction size
Other
Voltage protection level
1.6kV
Integrated short-circuit protection
Yes
Max. overcurrent protection device, series connection (fuse)
0A
Short-circuit breaking capacity (Isccr)
40kA
Leakage-current free
No
Category type 2
No
Signalling at the device
Optic
Degree of protection (IP)
Other
From same serie
50172

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
System configuration IT
System configuration DC
System configuration TN-C-S
System configuration TN
System configuration TN-S
System configuration TT
Number of conductors (without earthing)
1
System configuration TN-C
System configuration other
Nominal voltage AC
660V
Nominal voltage DC
0V
Max. discharge surge current (8/20)
40kA
Nominal discharge surge current (8/20)
40kA
Max. PV-voltage
0V
Max. continuous voltage DC
0V
Max. continuous voltage AC
1000V
Voltage protection level L-N
1kV
Integrated backup fuse
Max. overcurrent protection device, parallel connection (fuse)
0A
Mounting method
On basic element
Integrated short-circuit protection selective to fuse gG
0A
Max. conductor cross section flexible (fine-strand)
150mm²
With remote signalling contact
Voltage protection level N-PE
0.66kV
Max. conductor cross section solid (solid, stranded)
150mm²
Construction size
Other
Voltage protection level
1.6kV
Integrated short-circuit protection
Max. overcurrent protection device, series connection (fuse)
0A
Short-circuit breaking capacity (Isccr)
40kA
Leakage-current free
Category type 2
Signalling at the device
Optic
Degree of protection (IP)
Other
From same serie