Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Built-in depth44.5mm
Rated insulation voltage Ui500V
Rated current1A
Release characteristicB
Number of protected poles1
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp6kV
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Current limiting class3
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Pollution degree3
Width in number of modular spacings1
Flush-mounted installationNo
Additional equipment possibleYes
Ambient temperature during operating-35 - 70°C
Connectable conductor cross section multi-wired1 - 16mm²
Over voltage category4
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F73101

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Built-in depth

44.5mm

Rated insulation voltage Ui

500V

Rated current

1A

Release characteristic

B

Number of protected poles

1

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

6kV

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Current limiting class

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Pollution degree

3

Width in number of modular spacings

1

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section multi-wired

1 .. 16mm²

Over voltage category

4

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.