  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated current63A
Number of protected poles1
Built-in depth44.5mm
Release characteristicD
Number of poles (total)1
Voltage typeAC/DC
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Frequency50 - 60Hz
Flush-mounted installationNo
Width in number of modular spacings1
Over voltage category4
Pollution degree3
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 35mm²
Ambient temperature during operating-35 - 70°C
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Current limiting class3
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Rated voltage230V
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F75163

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

63A

Number of protected poles

1

Built-in depth

44.5mm

Release characteristic

D

Number of poles (total)

1

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Frequency

50 .. 60Hz

Flush-mounted installation

Width in number of modular spacings

1

Over voltage category

4

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 35mm²

Ambient temperature during operating

-35 .. 70°C

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Current limiting class

3

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated voltage

230V

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.