Technical specifications

Rated current1A
Built-in depth44.5mm
Voltage typeAC/DC
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Explosion-proofNo
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Frequency50 - 60Hz
Release characteristicD
Additional equipment possibleYes
Over voltage category4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Flush-mounted installationNo
Width in number of modular spacings3
Number of poles (total)3
Pollution degree3
Ambient temperature during operating-35 - 70°C
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Number of protected poles3
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired1 - 16mm²
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F75301 | Prekidac Minijaturni IC60N 3P 1A D

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated current

1A

Built-in depth

44.5mm

Voltage type

AC/DC

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Explosion-proof

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Frequency

50 .. 60Hz

Release characteristic

D

Additional equipment possible

Over voltage category

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Flush-mounted installation

Width in number of modular spacings

3

Number of poles (total)

3

Pollution degree

3

Ambient temperature during operating

-35 .. 70°C

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Number of protected poles

3

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

1 .. 16mm²

Rated impulse withstand voltage Uimp

6kV