Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Release characteristicD
Rated current4A
Number of protected poles4
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated voltage400V
Voltage typeAC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Width in number of modular spacings4
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Ambient temperature during operating-35 - 70°C
Pollution degree3
Connectable conductor cross section multi-wired1 - 16mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Explosion-proofNo
Over voltage category4
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F75404

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Release characteristic

D

Rated current

4A

Number of protected poles

4

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Width in number of modular spacings

4

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Additional equipment possible

Ambient temperature during operating

-35 .. 70°C

Pollution degree

3

Connectable conductor cross section multi-wired

1 .. 16mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Explosion-proof

Over voltage category

4

Connectable conductor cross section solid-core

1 .. 25mm²