Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Number of protected poles4
Concurrently switching neutral conductorNo
Explosion-proofNo
Over voltage category4
Connectable conductor cross section solid-core1 - 35mm²
Degree of protection (IP)IP20
Pollution degree3
Width in number of modular spacings4
Frequency50 - 60Hz
Rated voltage400V
Rated insulation voltage Ui500V
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-35 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Additional equipment possibleYes
Current limiting class3
Rated impulse withstand voltage Uimp6kV
Rated current50A
Release characteristicD
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F75450 | Prekidac Minijaturni IC60N 4P 50A D

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Number of protected poles

4

Concurrently switching neutral conductor

Explosion-proof

Over voltage category

4

Connectable conductor cross section solid-core

1 .. 35mm²

Degree of protection (IP)

IP20

Pollution degree

3

Width in number of modular spacings

4

Frequency

50 .. 60Hz

Rated voltage

400V

Rated insulation voltage Ui

500V

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-35 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Additional equipment possible

Current limiting class

3

Rated impulse withstand voltage Uimp

6kV

Rated current

50A

Release characteristic

D

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.