Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Release characteristicC
Number of protected poles4
Number of poles (total)4
Rated voltage400V
Rated current3A
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V70kA
Rated impulse withstand voltage Uimp6kV
Frequency50 - 60Hz
Current limiting class3
Over voltage category4
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Degree of protection (IP)IP20
Width in number of modular spacings4
Ambient temperature during operating-35 - 70°C
Pollution degree3
Connectable conductor cross section multi-wired1 - 16mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V70kA
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F84403

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Release characteristic

C

Number of protected poles

4

Number of poles (total)

4

Rated voltage

400V

Rated current

3A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

70kA

Rated impulse withstand voltage Uimp

6kV

Frequency

50 .. 60Hz

Current limiting class

3

Over voltage category

4

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Ambient temperature during operating

-35 .. 70°C

Pollution degree

3

Connectable conductor cross section multi-wired

1 .. 16mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

70kA

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.