Technical specifications

Rated insulation voltage Ui500V
Rated current4A
Current limiting class3
Pollution degree3
Release characteristicD
Over voltage category4
Rated voltage230V
Frequency50 - 60Hz
Voltage typeAC/DC
Built-in depth44.5mm
Number of protected poles1
Width in number of modular spacings1
Explosion-proofNo
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating-35 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V70kA
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 16mm²
Flush-mounted installationNo
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F85104 | Prekidac Minijaturni IC60H 1P 4A D

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated insulation voltage Ui

500V

Rated current

4A

Current limiting class

3

Pollution degree

3

Release characteristic

D

Over voltage category

4

Rated voltage

230V

Frequency

50 .. 60Hz

Voltage type

AC/DC

Built-in depth

44.5mm

Number of protected poles

1

Width in number of modular spacings

1

Explosion-proof

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

-35 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

70kA

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 16mm²

Flush-mounted installation

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.