Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristicD
Rated current0.5A
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp6kV
Built-in depth44.5mm
Rated insulation voltage Ui500V
Number of protected poles2
Voltage typeAC/DC
Rated voltage400V
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V70kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V70kA
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Over voltage category4
Pollution degree3
Ambient temperature during operating-35 - 70°C
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Width in number of modular spacings2
Connectable conductor cross section multi-wired1 - 16mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F85270

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristic

D

Rated current

0.5A

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

6kV

Built-in depth

44.5mm

Rated insulation voltage Ui

500V

Number of protected poles

2

Voltage type

AC/DC

Rated voltage

400V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

70kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

70kA

Flush-mounted installation

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Over voltage category

4

Pollution degree

3

Ambient temperature during operating

-35 .. 70°C

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

1 .. 16mm²

Additional equipment possible

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.