Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth44.5mm
Release characteristicZ
Current limiting class3
Frequency50 - 60Hz
Rated voltage230V
Over voltage category4
Additional equipment possibleYes
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Number of poles (total)1
Concurrently switching neutral conductorNo
Number of protected poles1
Rated current1A
Rated impulse withstand voltage Uimp6kV
Voltage typeAC/DC
Flush-mounted installationNo
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated insulation voltage Ui500V
Width in number of modular spacings1
Ambient temperature during operating-35 - 70°C
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 16mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F92101

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

44.5mm

Release characteristic

Z

Current limiting class

3

Frequency

50 .. 60Hz

Rated voltage

230V

Over voltage category

4

Additional equipment possible

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Number of poles (total)

1

Concurrently switching neutral conductor

Number of protected poles

1

Rated current

1A

Rated impulse withstand voltage Uimp

6kV

Voltage type

AC/DC

Flush-mounted installation

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated insulation voltage Ui

500V

Width in number of modular spacings

1

Ambient temperature during operating

-35 .. 70°C

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 16mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.