Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Frequency50 - 60Hz
Rated current6A
Rated voltage230V
Voltage typeAC/DC
Pollution degree3
Width in number of modular spacings1
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Explosion-proofNo
Over voltage category4
Ambient temperature during operating-35 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Release characteristicZ
Current limiting class3
Additional equipment possibleYes
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp6kV
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Number of protected poles1
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired1 - 16mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F92106

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Frequency

50 .. 60Hz

Rated current

6A

Rated voltage

230V

Voltage type

AC/DC

Pollution degree

3

Width in number of modular spacings

1

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Explosion-proof

Over voltage category

4

Ambient temperature during operating

-35 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Release characteristic

Z

Current limiting class

3

Additional equipment possible

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

6kV

Concurrently switching neutral conductor

Flush-mounted installation

Number of protected poles

1

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

1 .. 16mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.