Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth44.5mm
Release characteristicZ
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated insulation voltage Ui500V
Rated voltage230V
Over voltage category4
Number of poles (total)1
Number of protected poles1
Voltage typeAC/DC
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Current limiting class3
Rated current1.6A
Frequency50 - 60Hz
Pollution degree3
Rated impulse withstand voltage Uimp6kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Ambient temperature during operating-35 - 70°C
Width in number of modular spacings1
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 16mm²
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F92172

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

44.5mm

Release characteristic

Z

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated insulation voltage Ui

500V

Rated voltage

230V

Over voltage category

4

Number of poles (total)

1

Number of protected poles

1

Voltage type

AC/DC

Flush-mounted installation

Concurrently switching neutral conductor

Current limiting class

3

Rated current

1.6A

Frequency

50 .. 60Hz

Pollution degree

3

Rated impulse withstand voltage Uimp

6kV

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Ambient temperature during operating

-35 .. 70°C

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 16mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.