Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Rated voltage400V
Number of protected poles2
Release characteristicZ
Voltage typeAC/DC
Rated current10A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Flush-mounted installationNo
Over voltage category4
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Current limiting class3
Pollution degree3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 16mm²
Ambient temperature during operating-35 - 70°C
Explosion-proofNo
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F92210

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Rated voltage

400V

Number of protected poles

2

Release characteristic

Z

Voltage type

AC/DC

Rated current

10A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Concurrently switching neutral conductor

Width in number of modular spacings

2

Flush-mounted installation

Over voltage category

4

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Current limiting class

3

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 16mm²

Ambient temperature during operating

-35 .. 70°C

Explosion-proof

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.