Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Release characteristicB
Rated voltage400V
Rated impulse withstand voltage Uimp6kV
Voltage typeAC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Current limiting class3
Number of poles (total)2
Rated current40A
Frequency50 - 60Hz
Number of protected poles2
Over voltage category4
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Ambient temperature during operating-35 - 70°C
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Width in number of modular spacings2
Explosion-proofNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core1 - 35mm²
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F93240

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Release characteristic

B

Rated voltage

400V

Rated impulse withstand voltage Uimp

6kV

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Current limiting class

3

Number of poles (total)

2

Rated current

40A

Frequency

50 .. 60Hz

Number of protected poles

2

Over voltage category

4

Concurrently switching neutral conductor

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Width in number of modular spacings

2

Explosion-proof

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

1 .. 35mm²

Flush-mounted installation

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.