  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency50 - 60Hz
Rated current40A
Built-in depth44.5mm
Rated voltage400V
Voltage typeAC/DC
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Current limiting class3
Rated insulation voltage Ui500V
Release characteristicB
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Flush-mounted installationNo
Width in number of modular spacings2
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
Additional equipment possibleYes
Over voltage category4
Pollution degree3
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Concurrently switching neutral conductorNo
Number of poles (total)2
Ambient temperature during operating-35 - 70°C
Connectable conductor cross section solid-core1 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F93240 | Prekidac Minijaturni IC60L 2P 40A B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency

50 .. 60Hz

Rated current

40A

Built-in depth

44.5mm

Rated voltage

400V

Voltage type

AC/DC

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Current limiting class

3

Rated insulation voltage Ui

500V

Release characteristic

B

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Flush-mounted installation

Width in number of modular spacings

2

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Additional equipment possible

Over voltage category

4

Pollution degree

3

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Concurrently switching neutral conductor

Number of poles (total)

2

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section solid-core

1 .. 35mm²