Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristicB
Over voltage category4
Built-in depth44.5mm
Rated current50A
Rated insulation voltage Ui500V
Current limiting class3
Frequency50 - 60Hz
Voltage typeAC/DC
Rated voltage400V
Degree of protection (IP)IP20
Width in number of modular spacings4
Explosion-proofNo
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Pollution degree3
Additional equipment possibleYes
Flush-mounted installationNo
Ambient temperature during operating-35 - 70°C
Concurrently switching neutral conductorNo
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Connectable conductor cross section solid-core1 - 35mm²
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F93450 | Prekidac Minijaturni IC60L 4P 50A B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristic

B

Over voltage category

4

Built-in depth

44.5mm

Rated current

50A

Rated insulation voltage Ui

500V

Current limiting class

3

Frequency

50 .. 60Hz

Voltage type

AC/DC

Rated voltage

400V

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Explosion-proof

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Pollution degree

3

Additional equipment possible

Flush-mounted installation

Ambient temperature during operating

-35 .. 70°C

Concurrently switching neutral conductor

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Connectable conductor cross section solid-core

1 .. 35mm²

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA