Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage typeAC/DC
Release characteristicC
Rated voltage400V
Rated current40A
Built-in depth44.5mm
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Over voltage category4
Current limiting class3
Explosion-proofNo
Degree of protection (IP)IP20
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Connectable conductor cross section multi-wired1 - 25mm²
Width in number of modular spacings3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Ambient temperature during operating-35 - 70°C
Concurrently switching neutral conductorNo
Number of poles (total)3
Connectable conductor cross section solid-core1 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Pollution degree3
Number of protected poles3
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F94340 | Prekidac Minijaturni IC60L 3P 40A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage type

AC/DC

Release characteristic

C

Rated voltage

400V

Rated current

40A

Built-in depth

44.5mm

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Over voltage category

4

Current limiting class

3

Explosion-proof

Degree of protection (IP)

IP20

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Width in number of modular spacings

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Ambient temperature during operating

-35 .. 70°C

Concurrently switching neutral conductor

Number of poles (total)

3

Connectable conductor cross section solid-core

1 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Pollution degree

3

Number of protected poles

3

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.