Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Voltage typeAC/DC
Rated current3A
Frequency50 - 60Hz
Over voltage category4
Explosion-proofNo
Pollution degree3
Number of protected poles4
Width in number of modular spacings4
Rated insulation voltage Ui500V
Release characteristicC
Degree of protection (IP)IP20
Current limiting class3
Rated voltage400V
Ambient temperature during operating-35 - 70°C
Connectable conductor cross section multi-wired1 - 16mm²
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Number of poles (total)4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F94403 | Prekidac Minijaturni IC60L 4P 3A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Voltage type

AC/DC

Rated current

3A

Frequency

50 .. 60Hz

Over voltage category

4

Explosion-proof

Pollution degree

3

Number of protected poles

4

Width in number of modular spacings

4

Rated insulation voltage Ui

500V

Release characteristic

C

Degree of protection (IP)

IP20

Current limiting class

3

Rated voltage

400V

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section multi-wired

1 .. 16mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Number of poles (total)

4

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation