Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Voltage typeAC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated impulse withstand voltage Uimp6kV
Current limiting class3
Frequency50 - 60Hz
Rated current6A
Over voltage category4
Release characteristicC
Rated voltage400V
Additional equipment possibleYes
Width in number of modular spacings4
Flush-mounted installationNo
Number of poles (total)4
Power loss1.3W
Number of protected poles4
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Degree of protection (IP)IP20
Explosion-proofNo
Ambient temperature during operating-35 - 70°C
Connectable conductor cross section multi-wired1 - 16mm²
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F94406

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated impulse withstand voltage Uimp

6kV

Current limiting class

3

Frequency

50 .. 60Hz

Rated current

6A

Over voltage category

4

Release characteristic

C

Rated voltage

400V

Additional equipment possible

Width in number of modular spacings

4

Flush-mounted installation

Number of poles (total)

4

Power loss

1.3W

Number of protected poles

4

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Degree of protection (IP)

IP20

Explosion-proof

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section multi-wired

1 .. 16mm²

Connectable conductor cross section solid-core

1 .. 25mm²