Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated current2A
Voltage typeAC/DC
Rated voltage230V
Built-in depth44.5mm
Frequency50 - 60Hz
Pollution degree3
Connectable conductor cross section solid-core1 - 25mm²
Number of protected poles1
Current limiting class3
Connectable conductor cross section multi-wired1 - 16mm²
Flush-mounted installationNo
Ambient temperature during operating-35 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Additional equipment possibleYes
Explosion-proofNo
Release characteristicK
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp6kV
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Over voltage category4
Width in number of modular spacings1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Number of poles (total)1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95102 | Prekidac Minijaturni IC60L 1P 2A K

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated current

2A

Voltage type

AC/DC

Rated voltage

230V

Built-in depth

44.5mm

Frequency

50 .. 60Hz

Pollution degree

3

Connectable conductor cross section solid-core

1 .. 25mm²

Number of protected poles

1

Current limiting class

3

Connectable conductor cross section multi-wired

1 .. 16mm²

Flush-mounted installation

Ambient temperature during operating

-35 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Additional equipment possible

Explosion-proof

Release characteristic

K

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

6kV

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Over voltage category

4

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Number of poles (total)

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.