Technical specifications

Degree of protection (IP)IP20
Voltage typeAC/DC
Width in number of modular spacings1
Rated voltage230V
Pollution degree3
Explosion-proofNo
Current limiting class3
Rated current10A
Over voltage category4
Rated insulation voltage Ui500V
Built-in depth44.5mm
Release characteristicK
Frequency50 - 60Hz
Number of protected poles1
Number of poles (total)1
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationNo
Ambient temperature during operating-35 - 70°C
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 16mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95110 | Prekidac Minijaturni IC60L 1P 10A K

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC/DC

Width in number of modular spacings

1

Rated voltage

230V

Pollution degree

3

Explosion-proof

Current limiting class

3

Rated current

10A

Over voltage category

4

Rated insulation voltage Ui

500V

Built-in depth

44.5mm

Release characteristic

K

Frequency

50 .. 60Hz

Number of protected poles

1

Number of poles (total)

1

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

Ambient temperature during operating

-35 .. 70°C

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 16mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA