Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth44.5mm
Release characteristicK
Rated voltage230V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated current20A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Frequency50 - 60Hz
Flush-mounted installationNo
Number of protected poles1
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings1
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Over voltage category4
Ambient temperature during operating-35 - 70°C
Voltage typeAC/DC
Number of poles (total)1
Current limiting class3
Connectable conductor cross section multi-wired1 - 16mm²
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95120

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

44.5mm

Release characteristic

K

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated current

20A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Frequency

50 .. 60Hz

Flush-mounted installation

Number of protected poles

1

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Over voltage category

4

Ambient temperature during operating

-35 .. 70°C

Voltage type

AC/DC

Number of poles (total)

1

Current limiting class

3

Connectable conductor cross section multi-wired

1 .. 16mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.