Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth44.5mm
Rated current32A
Number of poles (total)1
Rated impulse withstand voltage Uimp6kV
Voltage typeAC/DC
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Degree of protection (IP)IP20
Number of protected poles1
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings1
Rated voltage230V
Explosion-proofNo
Current limiting class3
Release characteristicK
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Over voltage category4
Ambient temperature during operating-35 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Connectable conductor cross section solid-core1 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95132

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

44.5mm

Rated current

32A

Number of poles (total)

1

Rated impulse withstand voltage Uimp

6kV

Voltage type

AC/DC

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Number of protected poles

1

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

1

Rated voltage

230V

Explosion-proof

Current limiting class

3

Release characteristic

K

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Over voltage category

4

Ambient temperature during operating

-35 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Connectable conductor cross section solid-core

1 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.