  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage typeAC/DC
Rated current1A
Built-in depth44.5mm
Rated voltage400V
Ambient temperature during operating-35 - 70°C
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Explosion-proofNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Pollution degree3
Current limiting class3
Additional equipment possibleYes
Release characteristicK
Connectable conductor cross section solid-core1 - 25mm²
Number of poles (total)2
Number of protected poles2
Connectable conductor cross section multi-wired1 - 16mm²
Over voltage category4
Width in number of modular spacings2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95201 | Prekidac Minijaturni IC60L 2P 1A K

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage type

AC/DC

Rated current

1A

Built-in depth

44.5mm

Rated voltage

400V

Ambient temperature during operating

-35 .. 70°C

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Explosion-proof

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Pollution degree

3

Current limiting class

3

Additional equipment possible

Release characteristic

K

Connectable conductor cross section solid-core

1 .. 25mm²

Number of poles (total)

2

Number of protected poles

2

Connectable conductor cross section multi-wired

1 .. 16mm²

Over voltage category

4

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA