Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Rated voltage400V
Rated current3A
Number of poles (total)2
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated impulse withstand voltage Uimp6kV
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Width in number of modular spacings2
Frequency50 - 60Hz
Pollution degree3
Over voltage category4
Release characteristicK
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 16mm²
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-35 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Voltage typeAC/DC
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Concurrently switching neutral conductorNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95203

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Rated voltage

400V

Rated current

3A

Number of poles (total)

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated impulse withstand voltage Uimp

6kV

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Width in number of modular spacings

2

Frequency

50 .. 60Hz

Pollution degree

3

Over voltage category

4

Release characteristic

K

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 16mm²

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-35 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Voltage type

AC/DC

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Concurrently switching neutral conductor

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.