  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristicK
Rated voltage400V
Rated current10A
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Number of poles (total)2
Built-in depth44.5mm
Voltage typeAC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Current limiting class3
Frequency50 - 60Hz
Over voltage category4
Additional equipment possibleYes
Flush-mounted installationNo
Width in number of modular spacings2
Explosion-proofNo
Number of protected poles2
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-35 - 70°C
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 16mm²
Pollution degree3
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95210

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristic

K

Rated voltage

400V

Rated current

10A

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

2

Built-in depth

44.5mm

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Current limiting class

3

Frequency

50 .. 60Hz

Over voltage category

4

Additional equipment possible

Flush-mounted installation

Width in number of modular spacings

2

Explosion-proof

Number of protected poles

2

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-35 .. 70°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 16mm²

Pollution degree

3

Concurrently switching neutral conductor

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.