Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Voltage typeAC/DC
Rated current40A
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Rated voltage400V
Current limiting class3
Over voltage category4
Ambient temperature during operating-35 - 70°C
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Release characteristicK
Additional equipment possibleYes
Number of poles (total)2
Pollution degree3
Connectable conductor cross section solid-core1 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Degree of protection (IP)IP20
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Width in number of modular spacings2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95240 | Prekidac Minijaturni IC60L 2P 40A K

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Voltage type

AC/DC

Rated current

40A

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Rated voltage

400V

Current limiting class

3

Over voltage category

4

Ambient temperature during operating

-35 .. 70°C

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Release characteristic

K

Additional equipment possible

Number of poles (total)

2

Pollution degree

3

Connectable conductor cross section solid-core

1 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Degree of protection (IP)

IP20

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Width in number of modular spacings

2