  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Rated current6A
Release characteristicK
Number of poles (total)3
Number of protected poles3
Rated voltage400V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Voltage typeAC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Flush-mounted installationNo
Over voltage category4
Concurrently switching neutral conductorNo
Current limiting class3
Additional equipment possibleYes
Pollution degree3
Degree of protection (IP)IP20
Width in number of modular spacings3
Ambient temperature during operating-35 - 70°C
Connectable conductor cross section multi-wired1 - 16mm²
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95306

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Rated current

6A

Release characteristic

K

Number of poles (total)

3

Number of protected poles

3

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Flush-mounted installation

Over voltage category

4

Concurrently switching neutral conductor

Current limiting class

3

Additional equipment possible

Pollution degree

3

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section multi-wired

1 .. 16mm²

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²