Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Number of poles (total)3
Release characteristicK
Number of protected poles3
Rated current50A
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp6kV
Rated voltage400V
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Voltage typeAC/DC
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Pollution degree3
Width in number of modular spacings3
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 35mm²
Over voltage category4
Current limiting class3
Ambient temperature during operating-35 - 70°C
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95350

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Number of poles (total)

3

Release characteristic

K

Number of protected poles

3

Rated current

50A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Voltage type

AC/DC

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Pollution degree

3

Width in number of modular spacings

3

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 35mm²

Over voltage category

4

Current limiting class

3

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.