  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Release characteristicK
Rated current1.6A
Voltage typeAC/DC
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui500V
Number of protected poles3
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Current limiting class3
Frequency50 - 60Hz
Over voltage category4
Flush-mounted installationNo
Ambient temperature during operating-35 - 70°C
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 16mm²
Width in number of modular spacings3
Connectable conductor cross section solid-core1 - 25mm²
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95372

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Release characteristic

K

Rated current

1.6A

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Current limiting class

3

Frequency

50 .. 60Hz

Over voltage category

4

Flush-mounted installation

Ambient temperature during operating

-35 .. 70°C

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 16mm²

Width in number of modular spacings

3

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Additional equipment possible