Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Number of poles (total)4
Release characteristicK
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Voltage typeAC/DC
Rated impulse withstand voltage Uimp6kV
Number of protected poles4
Rated current2A
Rated voltage400V
Rated insulation voltage Ui500V
Flush-mounted installationNo
Frequency50 - 60Hz
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Over voltage category4
Pollution degree3
Width in number of modular spacings4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Ambient temperature during operating-35 - 70°C
Connectable conductor cross section multi-wired1 - 16mm²
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95402

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Number of poles (total)

4

Release characteristic

K

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

6kV

Number of protected poles

4

Rated current

2A

Rated voltage

400V

Rated insulation voltage Ui

500V

Flush-mounted installation

Frequency

50 .. 60Hz

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Over voltage category

4

Pollution degree

3

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section multi-wired

1 .. 16mm²

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.