Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth44.5mm
Rated insulation voltage Ui500V
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Voltage typeAC/DC
Rated voltage400V
Current limiting class3
Flush-mounted installationNo
Over voltage category4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Concurrently switching neutral conductorNo
Width in number of modular spacings4
Degree of protection (IP)IP20
Pollution degree3
Connectable conductor cross section solid-core1 - 35mm²
Frequency50 - 60Hz
Explosion-proofNo
Release characteristicK
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-35 - 70°C
Additional equipment possibleYes
Rated current32A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9F95432

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

44.5mm

Rated insulation voltage Ui

500V

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Voltage type

AC/DC

Rated voltage

400V

Current limiting class

3

Flush-mounted installation

Over voltage category

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Concurrently switching neutral conductor

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Pollution degree

3

Connectable conductor cross section solid-core

1 .. 35mm²

Frequency

50 .. 60Hz

Explosion-proof

Release characteristic

K

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-35 .. 70°C

Additional equipment possible

Rated current

32A

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.