Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC-V
Voltage protection level L-N1kV
Nominal voltage DC-V
Max. PV-voltage-V
System configuration ITNo
System configuration DCNo
System configuration TNNo
System configuration TN-C-SNo
Number of conductors (without earthing)2
System configuration TTNo
System configuration TN-CYes
System configuration otherNo
Nominal voltage AC350V
Max. discharge surge current (8/20)8kA
Max. continuous voltage AC350V
System configuration TN-SNo
Voltage protection level1kV
Max. overcurrent protection device, parallel connection (fuse)25A
Nominal discharge surge current (8/20)2.5kA
Voltage protection level N-PE1kV
Max. overcurrent protection device, series connection (fuse)80A
Short-circuit breaking capacity (Isccr)50kA
Leakage-current freeNo
Integrated backup fuseNo
Mounting methodDIN rail (top hat rail) 35 mm
Integrated short-circuit protectionNo
With remote signalling contactNo
Construction size4 modular spacing
Category type 2Yes
Signalling at the deviceOptic
Degree of protection (IP)IP20
Max. conductor cross section solid (solid, stranded)25mm²
Max. conductor cross section flexible (fine-strand)16mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L08200

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC

-V

Voltage protection level L-N

1kV

Nominal voltage DC

-V

Max. PV-voltage

-V

System configuration IT

System configuration DC

System configuration TN

System configuration TN-C-S

Number of conductors (without earthing)

2

System configuration TT

System configuration TN-C

System configuration other

Nominal voltage AC

350V

Max. discharge surge current (8/20)

8kA

Max. continuous voltage AC

350V

System configuration TN-S

Voltage protection level

1kV

Max. overcurrent protection device, parallel connection (fuse)

25A

Nominal discharge surge current (8/20)

2.5kA

Voltage protection level N-PE

1kV

Max. overcurrent protection device, series connection (fuse)

80A

Short-circuit breaking capacity (Isccr)

50kA

Leakage-current free

Integrated backup fuse

Mounting method

DIN rail (top hat rail) 35 mm

Integrated short-circuit protection

With remote signalling contact

Construction size

4 modular spacing

Category type 2

Signalling at the device

Optic

Degree of protection (IP)

IP20

Max. conductor cross section solid (solid, stranded)

25mm²

Max. conductor cross section flexible (fine-strand)

16mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.