Technical specifications

Construction size4 modular spacing
Category type 2Yes
Max. continuous voltage AC350V
Mounting methodDIN rail (top hat rail) 35 mm
Nominal voltage DC-V
Voltage protection level1kV
Number of conductors (without earthing)2
With remote signalling contactNo
Voltage protection level L-N1kV
System configuration TN-CYes
Max. continuous voltage DC-V
Signalling at the deviceOptic
System configuration TNNo
Max. PV-voltage-V
Max. conductor cross section solid (solid, stranded)25mm²
Integrated backup fuseNo
Voltage protection level N-PE1kV
System configuration otherNo
Max. conductor cross section flexible (fine-strand)16mm²
System configuration DCNo
Short-circuit breaking capacity (Isccr)50kA
Leakage-current freeNo
Integrated short-circuit protectionNo
System configuration ITNo
System configuration TN-SNo
System configuration TN-C-SNo
Max. discharge surge current (8/20)8kA
Max. overcurrent protection device, parallel connection (fuse)25A
Max. overcurrent protection device, series connection (fuse)80A
System configuration TTNo
Nominal discharge surge current (8/20)2.5kA
Nominal voltage AC350V
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L08200 | Odvodnik Pren. iPRD 8 2P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Construction size

4 modular spacing

Category type 2

Max. continuous voltage AC

350V

Mounting method

DIN rail (top hat rail) 35 mm

Nominal voltage DC

-V

Voltage protection level

1kV

Number of conductors (without earthing)

2

With remote signalling contact

Voltage protection level L-N

1kV

System configuration TN-C

Max. continuous voltage DC

-V

Signalling at the device

Optic

System configuration TN

Max. PV-voltage

-V

Max. conductor cross section solid (solid, stranded)

25mm²

Integrated backup fuse

Voltage protection level N-PE

1kV

System configuration other

Max. conductor cross section flexible (fine-strand)

16mm²

System configuration DC

Short-circuit breaking capacity (Isccr)

50kA

Leakage-current free

Integrated short-circuit protection

System configuration IT

System configuration TN-S

System configuration TN-C-S

Max. discharge surge current (8/20)

8kA

Max. overcurrent protection device, parallel connection (fuse)

25A

Max. overcurrent protection device, series connection (fuse)

80A

System configuration TT

Nominal discharge surge current (8/20)

2.5kA

Nominal voltage AC

350V

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.