Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Construction size2 modular spacing
Number of conductors (without earthing)1
Mounting methodDIN rail (top hat rail) 35 mm
Max. continuous voltage AC350V
With remote signalling contactNo
Voltage protection level1kV
Category type 2Yes
Nominal voltage DC-V
Max. PV-voltage-V
Voltage protection level L-N1.1kV
Signalling at the deviceOptic
System configuration TNNo
Max. conductor cross section flexible (fine-strand)35mm²
Max. continuous voltage DC-V
System configuration ITNo
System configuration TN-SYes
System configuration TN-CNo
Max. conductor cross section solid (solid, stranded)35mm²
System configuration TTYes
Integrated backup fuseNo
System configuration DCNo
Voltage protection level N-PE1.4kV
Max. discharge surge current (8/20)8kA
Max. overcurrent protection device, parallel connection (fuse)25A
Max. overcurrent protection device, series connection (fuse)80A
Short-circuit breaking capacity (Isccr)50kA
System configuration TN-C-SNo
System configuration otherNo
Leakage-current freeNo
Integrated short-circuit protectionNo
Nominal discharge surge current (8/20)2.5kA
Nominal voltage AC230V
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L08500 | Odvodnik Pren. iPRD 8 1P+N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Construction size

2 modular spacing

Number of conductors (without earthing)

1

Mounting method

DIN rail (top hat rail) 35 mm

Max. continuous voltage AC

350V

With remote signalling contact

Voltage protection level

1kV

Category type 2

Nominal voltage DC

-V

Max. PV-voltage

-V

Voltage protection level L-N

1.1kV

Signalling at the device

Optic

System configuration TN

Max. conductor cross section flexible (fine-strand)

35mm²

Max. continuous voltage DC

-V

System configuration IT

System configuration TN-S

System configuration TN-C

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration TT

Integrated backup fuse

System configuration DC

Voltage protection level N-PE

1.4kV

Max. discharge surge current (8/20)

8kA

Max. overcurrent protection device, parallel connection (fuse)

25A

Max. overcurrent protection device, series connection (fuse)

80A

Short-circuit breaking capacity (Isccr)

50kA

System configuration TN-C-S

System configuration other

Leakage-current free

Integrated short-circuit protection

Nominal discharge surge current (8/20)

2.5kA

Nominal voltage AC

230V

Degree of protection (IP)

IP20