Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration TN-C
No
System configuration DC
No
System configuration TN-C-S
No
System configuration TN-S
Yes
System configuration TT
Yes
System configuration IT
No
System configuration TN
No
System configuration other
No
Max. discharge surge current (8/20)
8kA
Number of conductors (without earthing)
3
Voltage protection level N-PE
1.1kV
Max. overcurrent protection device, parallel connection (fuse)
25A
Max. continuous voltage AC
350V
Voltage protection level
1.2kV
Integrated backup fuse
No
Nominal discharge surge current (8/20)
2.5kA
Voltage protection level L-N
1.1kV
Leakage-current free
No
Max. overcurrent protection device, series connection (fuse)
80A
Nominal voltage AC
400V
With remote signalling contact
No
Max. conductor cross section solid (solid, stranded)
35mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Construction size
4 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Signalling at the device
Optic
Category type 2
Yes
Short-circuit breaking capacity (Isccr)
50kA
Integrated short-circuit protection
No
Degree of protection (IP)
IP20
From same serie
A9L08600

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration TN-C
System configuration DC
System configuration TN-C-S
System configuration TN-S
System configuration TT
System configuration IT
System configuration TN
System configuration other
Max. discharge surge current (8/20)
8kA
Number of conductors (without earthing)
3
Voltage protection level N-PE
1.1kV
Max. overcurrent protection device, parallel connection (fuse)
25A
Max. continuous voltage AC
350V
Voltage protection level
1.2kV
Integrated backup fuse
Nominal discharge surge current (8/20)
2.5kA
Voltage protection level L-N
1.1kV
Leakage-current free
Max. overcurrent protection device, series connection (fuse)
80A
Nominal voltage AC
400V
With remote signalling contact
Max. conductor cross section solid (solid, stranded)
35mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Construction size
4 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Signalling at the device
Optic
Category type 2
Short-circuit breaking capacity (Isccr)
50kA
Integrated short-circuit protection
Degree of protection (IP)
IP20
From same serie