  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mounting methodDIN rail (top hat rail) 35 mm
System configuration otherNo
Category type 2Yes
Max. continuous voltage AC350V
Construction sizeOther
Max. continuous voltage DC-V
Nominal discharge surge current (8/20)5kA
Signalling at the deviceOptic
Max. conductor cross section solid (solid, stranded)25mm²
Nominal voltage AC400V
Max. conductor cross section flexible (fine-strand)25mm²
With remote signalling contactYes
System configuration DCNo
System configuration ITNo
Voltage protection level L-N1.5kV
System configuration TNNo
System configuration TN-SYes
Nominal voltage DC-V
Voltage protection level N-PE1.5kV
System configuration TTYes
System configuration TN-CNo
Max. PV-voltage-V
Number of conductors (without earthing)4
Integrated backup fuseNo
Voltage protection level1.5kV
Degree of protection (IP)IP20
Leakage-current freeNo
System configuration TN-C-SNo
Max. discharge surge current (8/20)20kA
Short-circuit breaking capacity (Isccr)25kA
Integrated short-circuit protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L16297 | Odvodnik Pren. iQUICK PRD 20R 3P+N Sig.

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mounting method

DIN rail (top hat rail) 35 mm

System configuration other

Category type 2

Max. continuous voltage AC

350V

Construction size

Other

Max. continuous voltage DC

-V

Nominal discharge surge current (8/20)

5kA

Signalling at the device

Optic

Max. conductor cross section solid (solid, stranded)

25mm²

Nominal voltage AC

400V

Max. conductor cross section flexible (fine-strand)

25mm²

With remote signalling contact

System configuration DC

System configuration IT

Voltage protection level L-N

1.5kV

System configuration TN

System configuration TN-S

Nominal voltage DC

-V

Voltage protection level N-PE

1.5kV

System configuration TT

System configuration TN-C

Max. PV-voltage

-V

Number of conductors (without earthing)

4

Integrated backup fuse

Voltage protection level

1.5kV

Degree of protection (IP)

IP20

Leakage-current free

System configuration TN-C-S

Max. discharge surge current (8/20)

20kA

Short-circuit breaking capacity (Isccr)

25kA

Integrated short-circuit protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.