Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Nominal discharge surge current (8/20)20kA
Mounting methodOn basic element
Voltage protection level1.5kV
Construction sizeOther
Nominal voltage DC-V
With remote signalling contactNo
Nominal voltage AC230V
Max. continuous voltage AC264V
Signalling at the deviceOptic
Category type 2Yes
Voltage protection level L-N-kV
Max. PV-voltage-V
Max. continuous voltage DC-V
System configuration DCNo
Degree of protection (IP)IP20
Integrated backup fuseNo
Max. conductor cross section solid (solid, stranded)-mm²
Max. conductor cross section flexible (fine-strand)-mm²
Voltage protection level N-PE-kV
System configuration TN-C-SNo
System configuration otherNo
System configuration ITNo
Max. discharge surge current (8/20)65kA
System configuration TNYes
Leakage-current freeNo
System configuration TTYes
System configuration TN-CNo
System configuration TN-SNo
Integrated short-circuit protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L16313 | Uložak Rezervni C Neutral

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Nominal discharge surge current (8/20)

20kA

Mounting method

On basic element

Voltage protection level

1.5kV

Construction size

Other

Nominal voltage DC

-V

With remote signalling contact

Nominal voltage AC

230V

Max. continuous voltage AC

264V

Signalling at the device

Optic

Category type 2

Voltage protection level L-N

-kV

Max. PV-voltage

-V

Max. continuous voltage DC

-V

System configuration DC

Degree of protection (IP)

IP20

Integrated backup fuse

Max. conductor cross section solid (solid, stranded)

-mm²

Max. conductor cross section flexible (fine-strand)

-mm²

Voltage protection level N-PE

-kV

System configuration TN-C-S

System configuration other

System configuration IT

Max. discharge surge current (8/20)

65kA

System configuration TN

Leakage-current free

System configuration TT

System configuration TN-C

System configuration TN-S

Integrated short-circuit protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.