Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage AC350V
Construction size2 modular spacing
Mounting methodDIN rail (top hat rail) 35 mm
Number of conductors (without earthing)1
Voltage protection level1.4kV
With remote signalling contactYes
Signalling at the deviceOptic
System configuration ITNo
Max. PV-voltage-V
Category type 2Yes
Integrated backup fuseNo
System configuration TN-CNo
Max. overcurrent protection device, series connection (fuse)80A
System configuration DCNo
Short-circuit breaking capacity (Isccr)50kA
System configuration TNNo
System configuration TN-C-SNo
Voltage protection level N-PE1.4kV
Max. conductor cross section solid (solid, stranded)25mm²
Nominal voltage DC-V
Integrated short-circuit protectionNo
Max. continuous voltage DC-V
System configuration otherNo
System configuration TTYes
System configuration TN-SYes
Max. conductor cross section flexible (fine-strand)16mm²
Max. discharge surge current (8/20)20kA
Max. overcurrent protection device, parallel connection (fuse)40A
Leakage-current freeNo
Voltage protection level L-N1.1kV
Nominal discharge surge current (8/20)5kA
Nominal voltage AC400V
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L20501 | Odvodnik Pren. iPRD 20R 1P+N sa Sig.

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage AC

350V

Construction size

2 modular spacing

Mounting method

DIN rail (top hat rail) 35 mm

Number of conductors (without earthing)

1

Voltage protection level

1.4kV

With remote signalling contact

Signalling at the device

Optic

System configuration IT

Max. PV-voltage

-V

Category type 2

Integrated backup fuse

System configuration TN-C

Max. overcurrent protection device, series connection (fuse)

80A

System configuration DC

Short-circuit breaking capacity (Isccr)

50kA

System configuration TN

System configuration TN-C-S

Voltage protection level N-PE

1.4kV

Max. conductor cross section solid (solid, stranded)

25mm²

Nominal voltage DC

-V

Integrated short-circuit protection

Max. continuous voltage DC

-V

System configuration other

System configuration TT

System configuration TN-S

Max. conductor cross section flexible (fine-strand)

16mm²

Max. discharge surge current (8/20)

20kA

Max. overcurrent protection device, parallel connection (fuse)

40A

Leakage-current free

Voltage protection level L-N

1.1kV

Nominal discharge surge current (8/20)

5kA

Nominal voltage AC

400V

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.