Technical specifications

Max. continuous voltage AC350V
Voltage protection level1.1kV
Construction size4 modular spacing
Nominal voltage AC400V
Nominal voltage DC-V
Nominal discharge surge current (8/20)5kA
With remote signalling contactNo
Number of conductors (without earthing)3
Mounting methodDIN rail (top hat rail) 35 mm
Voltage protection level N-PE1.4kV
Category type 2Yes
Max. continuous voltage DC-V
System configuration DCNo
Signalling at the deviceOptic
System configuration TTYes
Degree of protection (IP)IP20
Short-circuit breaking capacity (Isccr)50kA
Max. overcurrent protection device, series connection (fuse)80A
System configuration TNNo
System configuration ITNo
Max. discharge surge current (8/20)20kA
System configuration TN-CNo
Max. conductor cross section flexible (fine-strand)35mm²
System configuration TN-C-SNo
Leakage-current freeNo
System configuration TN-SYes
Voltage protection level L-N1.1kV
System configuration otherNo
Max. PV-voltage-V
Integrated backup fuseNo
Max. overcurrent protection device, parallel connection (fuse)40A
Integrated short-circuit protectionNo
Max. conductor cross section solid (solid, stranded)35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L20600 | Odvodnik Pren. iPRD 20 3P+N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage AC

350V

Voltage protection level

1.1kV

Construction size

4 modular spacing

Nominal voltage AC

400V

Nominal voltage DC

-V

Nominal discharge surge current (8/20)

5kA

With remote signalling contact

Number of conductors (without earthing)

3

Mounting method

DIN rail (top hat rail) 35 mm

Voltage protection level N-PE

1.4kV

Category type 2

Max. continuous voltage DC

-V

System configuration DC

Signalling at the device

Optic

System configuration TT

Degree of protection (IP)

IP20

Short-circuit breaking capacity (Isccr)

50kA

Max. overcurrent protection device, series connection (fuse)

80A

System configuration TN

System configuration IT

Max. discharge surge current (8/20)

20kA

System configuration TN-C

Max. conductor cross section flexible (fine-strand)

35mm²

System configuration TN-C-S

Leakage-current free

System configuration TN-S

Voltage protection level L-N

1.1kV

System configuration other

Max. PV-voltage

-V

Integrated backup fuse

Max. overcurrent protection device, parallel connection (fuse)

40A

Integrated short-circuit protection

Max. conductor cross section solid (solid, stranded)

35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.