Number of conductors (without earthing)4
Mounting methodDIN rail (top hat rail) 35 mm
With remote signalling contactNo
Nominal voltage AC350V
Voltage protection level1.6kV
Nominal voltage DC-V
System configuration TTNo
Nominal discharge surge current (8/20)15kA
Construction size4 modular spacing
Max. continuous voltage AC350V
Category type 2Yes
Max. conductor cross section flexible (fine-strand)16mm²
Max. continuous voltage DC-V
Integrated backup fuseNo
Degree of protection (IP)IP20
System configuration TNNo
System configuration TN-SNo
System configuration TN-C-SNo
Max. PV-voltage400V
System configuration ITNo
System configuration otherNo
Voltage protection level N-PE1.4kV
Signalling at the deviceOptic
System configuration TN-CYes
Max. conductor cross section solid (solid, stranded)25mm²
Voltage protection level L-N-kV
System configuration DCNo
Max. discharge surge current (8/20)40kA
Max. overcurrent protection device, parallel connection (fuse)63A
Integrated short-circuit protectionNo
Max. overcurrent protection device, series connection (fuse)80A
Short-circuit breaking capacity (Isccr)50kA
Leakage-current freeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L40400 | Odvodnik Pren. iPRD 40 4P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of conductors (without earthing)

4

Mounting method

DIN rail (top hat rail) 35 mm

With remote signalling contact

Nominal voltage AC

350V

Voltage protection level

1.6kV

Nominal voltage DC

-V

System configuration TT

Nominal discharge surge current (8/20)

15kA

Construction size

4 modular spacing

Max. continuous voltage AC

350V

Category type 2

Max. conductor cross section flexible (fine-strand)

16mm²

Max. continuous voltage DC

-V

Integrated backup fuse

Degree of protection (IP)

IP20

System configuration TN

System configuration TN-S

System configuration TN-C-S

Max. PV-voltage

400V

System configuration IT

System configuration other

Voltage protection level N-PE

1.4kV

Signalling at the device

Optic

System configuration TN-C

Max. conductor cross section solid (solid, stranded)

25mm²

Voltage protection level L-N

-kV

System configuration DC

Max. discharge surge current (8/20)

40kA

Max. overcurrent protection device, parallel connection (fuse)

63A

Integrated short-circuit protection

Max. overcurrent protection device, series connection (fuse)

80A

Short-circuit breaking capacity (Isccr)

50kA

Leakage-current free