Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC-V
Voltage protection level L-N-kV
Nominal voltage DC-V
Max. PV-voltage400V
System configuration TN-CYes
System configuration ITNo
System configuration TNNo
System configuration DCNo
Nominal voltage AC350V
Max. discharge surge current (8/20)40kA
Number of conductors (without earthing)4
System configuration otherNo
System configuration TN-C-SNo
Voltage protection level1.6kV
Voltage protection level N-PE1.6kV
System configuration TN-SNo
Nominal discharge surge current (8/20)15kA
Max. continuous voltage AC350V
System configuration TTNo
Integrated backup fuseNo
Max. overcurrent protection device, parallel connection (fuse)63A
Max. overcurrent protection device, series connection (fuse)80A
Leakage-current freeNo
Max. conductor cross section solid (solid, stranded)25mm²
With remote signalling contactYes
Construction size4 modular spacing
Short-circuit breaking capacity (Isccr)50kA
Max. conductor cross section flexible (fine-strand)16mm²
Integrated short-circuit protectionNo
Degree of protection (IP)IP20
Mounting methodDIN rail (top hat rail) 35 mm
Category type 2Yes
Signalling at the deviceOptic
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L40401

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC

-V

Voltage protection level L-N

-kV

Nominal voltage DC

-V

Max. PV-voltage

400V

System configuration TN-C

System configuration IT

System configuration TN

System configuration DC

Nominal voltage AC

350V

Max. discharge surge current (8/20)

40kA

Number of conductors (without earthing)

4

System configuration other

System configuration TN-C-S

Voltage protection level

1.6kV

Voltage protection level N-PE

1.6kV

System configuration TN-S

Nominal discharge surge current (8/20)

15kA

Max. continuous voltage AC

350V

System configuration TT

Integrated backup fuse

Max. overcurrent protection device, parallel connection (fuse)

63A

Max. overcurrent protection device, series connection (fuse)

80A

Leakage-current free

Max. conductor cross section solid (solid, stranded)

25mm²

With remote signalling contact

Construction size

4 modular spacing

Short-circuit breaking capacity (Isccr)

50kA

Max. conductor cross section flexible (fine-strand)

16mm²

Integrated short-circuit protection

Degree of protection (IP)

IP20

Mounting method

DIN rail (top hat rail) 35 mm

Category type 2

Signalling at the device