Technical specifications

Mounting methodDIN rail (top hat rail) 35 mm
Nominal voltage AC400V
Construction size4 modular spacing
Number of conductors (without earthing)4
With remote signalling contactYes
Max. continuous voltage AC350V
Voltage protection level1.5kV
Nominal discharge surge current (8/20)20kA
Nominal voltage DC-V
Integrated backup fuseNo
Max. conductor cross section solid (solid, stranded)35mm²
System configuration DCNo
Degree of protection (IP)IP20
System configuration ITNo
System configuration TTYes
Voltage protection level N-PE1.5kV
Max. continuous voltage DC-V
Signalling at the deviceOptic
Voltage protection level L-N1.5kV
Category type 2Yes
System configuration TN-SYes
Max. conductor cross section flexible (fine-strand)35mm²
System configuration TNNo
System configuration otherNo
Max. PV-voltage-V
System configuration TN-CNo
Short-circuit breaking capacity (Isccr)50kA
Max. discharge surge current (8/20)65kA
System configuration TN-C-SNo
Integrated short-circuit protectionNo
Leakage-current freeNo
Max. overcurrent protection device, series connection (fuse)80A
Max. overcurrent protection device, parallel connection (fuse)80A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L65601

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mounting method

DIN rail (top hat rail) 35 mm

Nominal voltage AC

400V

Construction size

4 modular spacing

Number of conductors (without earthing)

4

With remote signalling contact

Max. continuous voltage AC

350V

Voltage protection level

1.5kV

Nominal discharge surge current (8/20)

20kA

Nominal voltage DC

-V

Integrated backup fuse

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration DC

Degree of protection (IP)

IP20

System configuration IT

System configuration TT

Voltage protection level N-PE

1.5kV

Max. continuous voltage DC

-V

Signalling at the device

Optic

Voltage protection level L-N

1.5kV

Category type 2

System configuration TN-S

Max. conductor cross section flexible (fine-strand)

35mm²

System configuration TN

System configuration other

Max. PV-voltage

-V

System configuration TN-C

Short-circuit breaking capacity (Isccr)

50kA

Max. discharge surge current (8/20)

65kA

System configuration TN-C-S

Integrated short-circuit protection

Leakage-current free

Max. overcurrent protection device, series connection (fuse)

80A

Max. overcurrent protection device, parallel connection (fuse)

80A