Technical specifications

Pollution degree3
Release characteristicB
Frequency50 - 60Hz
Over voltage category4
Current limiting class3
Rated insulation voltage Ui500V
Rated current100A
Rated voltage400V
Built-in depth44mm
Voltage typeAC
Width in number of modular spacings4.5
Explosion-proofNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core1.5 - 50mm²
Connectable conductor cross section multi-wired1 - 35mm²
Rated impulse withstand voltage Uimp6kV
Ambient temperature during operating-25 - 70°C
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Additional equipment possibleYes
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N18350 | Prekidac Minijat. C120N 10KA 3P 100 B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Pollution degree

3

Release characteristic

B

Frequency

50 .. 60Hz

Over voltage category

4

Current limiting class

3

Rated insulation voltage Ui

500V

Rated current

100A

Rated voltage

400V

Built-in depth

44mm

Voltage type

AC

Width in number of modular spacings

4.5

Explosion-proof

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated impulse withstand voltage Uimp

6kV

Ambient temperature during operating

-25 .. 70°C

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Additional equipment possible

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.