Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated current80A
Voltage typeAC
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Rated insulation voltage Ui500V
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1.5 - 50mm²
Width in number of modular spacings4.5
Built-in depth44mm
Pollution degree3
Over voltage category4
Number of protected poles3
Current limiting class3
Release characteristicC
Number of poles (total)3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Flush-mounted installationNo
Rated voltage400V
Ambient temperature during operating-25 - 70°C
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N18365 | Prekidac Minijat. C120N 10KA 3P 80A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated current

80A

Voltage type

AC

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1.5 .. 50mm²

Width in number of modular spacings

4.5

Built-in depth

44mm

Pollution degree

3

Over voltage category

4

Number of protected poles

3

Current limiting class

3

Release characteristic

C

Number of poles (total)

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Flush-mounted installation

Rated voltage

400V

Ambient temperature during operating

-25 .. 70°C

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.